range | TeSys |
|
---|---|---|
product name | TeSys F |
|
product or component type | Contactor |
|
device short name | LC1F |
|
contactor application | Motor control Resistive load |
|
Utilization category | AC-3 AC-4 AC-1 |
|
poles description | 3P |
|
power pole contact composition | 3 NO |
|
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
|
[Ie] rated operational current | 400 A (at <40 °C) at <= 440 V AC AC-1 330 A (at <55 °C) at <= 440 V AC AC-3 |
|
motor power kW | 160 kW at 380...400 V AC 50/60 Hz (AC-3) 180 kW at 415 V AC 50/60 Hz (AC-3) 200 kW at 440 V AC 50/60 Hz (AC-3) 200 kW at 500 V AC 50/60 Hz (AC-3) 220 kW at 660...690 V AC 50/60 Hz (AC-3) 160 kW at 1000 V AC 50/60 Hz (AC-3) 100 kW at 220...230 V AC 50/60 Hz (AC-3) 59 kW at 400 V AC 50/60 Hz (AC-4) |
|
[Uc] control circuit voltage | 220 V AC 40...400 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
|
---|---|---|
overvoltage category | III |
|
[Ith] conventional free air thermal current | 400 A (at 40 °C) |
|
rated breaking capacity | 2640 A conforming to IEC 60947-4-1 |
|
[Icw] rated short-time withstand current | 2650 A 40 °C - 10 s 1800 A 40 °C - 30 s 1300 A 40 °C - 1 min 900 A 40 °C - 3 min 750 A 40 °C - 10 min |
|
associated fuse rating | 400 A aM at <= 440 V 500 A gG at <= 440 V |
|
average impedance | 0.28 mOhm - Ith 400 A 50 Hz |
|
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
|
power dissipation per pole | 44 W AC-1 31 W AC-3 |
|
mounting support | Plate |
|
standards | EN 60947-1 EN 60947-4-1 JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1 |
|
product certifications | LROS (Lloyds register of shipping) CB UL BV ABS RMRoS RINA CSA DNV |
|
connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: lugs-ring terminals 1 cable(s) 240 mm² Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm Power circuit: bolted connection |
|
tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
|
control circuit voltage limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.35...0.55 Uc 40...400 Hz (at 55 °C) |
|
inrush power in VA | 650 VA 40...400 Hz cos phi 0.9 (at 20 °C) |
|
hold-in power consumption in VA | 10 VA 40...400 Hz cos phi 0.9 (at 20 °C) |
|
heat dissipation | 8 W |
|
operating time | 40...65 ms closing 100...170 ms opening |
|
mechanical durability | 10 Mcycles |
|
maximum operating rate | 2400 cyc/h 55 °C |
|
compatibility code | LC1F |
|
motor power range | 55…100 kW at 200…240 V 3 phases 110…220 kW at 480…500 V 3 phases 110…220 kW at 380…440 V 3 phases |
|
motor starter type | Direct on-line contactor |
|
contactor coil voltage | 220 V AC standard |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 |
|
---|---|---|
protective treatment | TH |
|
ambient air temperature for operation |