Functions & Features :

1) Reset Switch : The reset switch enables the detector to be manually reset during registering and testing and it is a process of system recovery;

2) Selectable Pulse Time : This feature sets the length of time that the pulse relay will be lasting for 1 Second or 0.5 Seconds ;

3) Pulse Relay Selection : The Pulse Relay may be configured to energize on detection of a vehicle or when the vehicle leaves the loop;

4) Sensitivity Reinforcement : This feature sets the un-detecting level to a maximum sensitivity to prevent failing to detect vehicles as big trucks;

5) Switch Sensibility Adjustable : 4 sensitivity setting are available on the switches to change sensitivity ;

6) Switch Frequency Adjustable : 4 frequency settings are available to prevent signal interference with neighboring loops ;

7) Filtering Option : This option is used to provide a delay between detection of the vehicle and switching of the output relay . This relay is normally used to prevent false detection of small or fast moving objects ;

8) Permanent Presence Option : This feature ensures the detection of the vehicle will be maintained when the vehicle stays within the loop area for extended periods


Technical Data:

1. Supply voltage: 110V AC                               

2. Voltage tolerance AC:  +10% / -15%

3. Voltage tolerance DC: ±15%

4. Power Consumption:  4.5VA                      

5. Operating temperature:  -20°C to +65°C        

6. Storage temperature:  -40°C to +85°C

7. Frequency range: 20 kHz to 170 kHz

8. Reaction time:  10ms                      

9. Signal lasting time: Unlimited / limited when loop is permanently covered 10 minutes

10. Sensitivity: Adjustable         

11. Loop inductance: Total loop plus connection wiring: 50μH to 1000μH; Ideal is 100μH to 300μH

12. Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter

13. Dimension: 78x40x108mm (L x W x H)

14. 10 dip switches


4422