Overview:
Specification:
Instruction for use:
1. Power on: Connect the DC + 5V voltage to the current terminal of the current monitor and wait for about 0.5 seconds.
2. External standard input: to determine whether the current we sense is within the allowable range, a reference voltage can be input by comparing the input terminals externally. The equation of the current amplitude corresponding to the reference voltage is: Uc = 2.5 + Ic * K. (When the input voltage is 5 V, the modulus coefficient for the sampling current K is 26 Mv/A).
3. Start current acquisition: Connect the sampling terminal of the current monitor to the circuit to be acquired in series.
4. digital tube display and serial port output: the current sampling data can be read from the digital tube and serial port, and the baud rate of the serial port is 9600 bps.
5. The protocol to send data frame is that the data frame has two bytes per frame, and the BCD code corresponds to the first byte of four bits high to indicate the positive and negative of the data. The BCD code corresponds to the lower 4 bits of the first byte and the upper 4 bits of the second byte to represent the integer of the current value, and the lower 4 bits of the second byte to represent the decimal of the current value.
Scope of delivery:
We offer a 30-day return and exchange service, and the return shipping costs are to be paid by the buyer. Returned items must be in acceptable condition, excluding any physical damage caused during shipping. If you need assistance with warranty and returns, please email us .