Application |
Measuring element |
ceramic-capacitive pressure measuring cell |
Application |
for industrial applications |
Media |
liquids and gases |
Medium temperature [°C] |
-25...80 |
Pressure rating |
10000 mbar |
145 psi |
1000 kPa |
290 inHg |
|
Min. bursting pressure |
30000 mbar |
450 psi |
3000 kPa |
880 inHg |
|
Type of pressure |
relative pressure |
Electrical data |
Operating voltage [V] |
18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 35 |
Min. insulation resistance [M?] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 0.3 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
150; (200 (...60 °C) 250 (...40 °C)) |
Switching frequency DC [Hz] |
< 170 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
-1000...1000 mbar |
-14.5...14.5 psi |
-100...100 kPa |
-29.4...29.4 inHg |
|
Set point SP |
-980...1000 mbar |
-14.3...14.5 psi |
-98...100 kPa |
-29...29.6 inHg |
|
Reset point rP |
-990...990 mbar |
-14.4...14.4 psi |
-99...99 kPa |
-29.2...29.4 inHg |
|
In steps of |
10 mbar |
0.1 psi |
1 kPa |
0.2 inHg |
|
Accuracy / deviations |
Switch point accuracy [% of the span] |
< ± 0,5 |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] |
< ± 0,25 |
Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] |
0,2; (-25...80 °C) |
Temperature coefficient span [% of the span / 10 K] |
0,2; (-25...80 °C) |
Response times |
Response time [ms] |
< 3 |
Delay time programmable dS, dr [s] |
0...50 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
IO-Link device ID |
406 d / 00 01 96 h |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
|