NEWPORT INFT-0 TEMPERATURE METER DISPLAY PROGRAMABLE NEW NOS $349
INFINITY INFT-0 Precision Digital Thermometer Thermocouple & RTD INFT-0-0-1-1-K
NEW OLD STOCK.
It looks like my customer road all TR on the back of this but not sure what they did to this. This has never been used.
MY CUSTOMER PUT THEIR LARGE LABEL ON TOP OF THIS UNIT. I TRIED TO REMOVE ALL OF IT BUT THERE IS STILL SOME RESIDUE.
The INFT thermocouple meter offers very high accuracy ensured by an advanced (patent applied for) thermocouple linearizing system. Accuracy for most thermocouple types is 0.2°C. The meter is front panel programmable for any of 9 thermocouple types. The INFT RTD input meter is programmable for any 6 to 6000ohm DIN or NIST platinum RTD. It provides a precision ultra-low constant current excitation to minimize self-heating errors and maximize stability.
SPECIFICATIONS Thermocouple Input: J, K, T, E, R, S, B, N, J DIN RTD Input: 100ohm Pt (385 or 392 curve) any 6 to 6Kohm NIST or DIN Pt and any linear RTD (10ohm Cu, etc); 2, 3 or 4 wire Step Response: 1 sec to 99.9% Warmup to Rated Accuracy: 50 min Operating Ambient: 0 to 50°C (32 to 122°F), 95%RH, non-condensing Storage Ambient: -40 to 85°C (-40 to 185°F) Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc Power Consumption: 6 W nominal, 10 W max. Normal Mode Rejection: 60 dB Common Mode Rejection: 120 dB Common Mode Voltage: 1500 V peak per Hv test Resolution: 15-bit Conversion: dual-slope technique Reading Rate: 3/sec or 13/sec, 60 Hz; 3/sec or 12/sec, 50 Hz Input Configuration: single-ended Polarity: unipolar/bipolar, programmable Span Adjustment: +0.00001 to 500,000, programmable Offset Adjustment: 0 to 999,999 or 0 to -99,999; programmable Sensor Excitation: 24 V at 25 mA 160 mA for 100ohm RTD 1.6 mA for 10ohm Cu Display: red or green 6-digit, 14-segment, 13.7 mm (0.54"); 4 alarm indicators Dimensions: 48 H x 96 W x 165 D mm (1.89" x 3.78" x 6.5") Panel Cutout: 45 H x 92 W mm (1.772" x 3.622"); 1/8 DIN Weight: 574 g (1.27 lb) TTL Outputs: four, isolated open collector; rated 150 mA at 1 V sink, 30 V open Dual Relays: form C, 7 A at 30 Vdc, 115 or 230 Vac BCD Output: isolated, tri-state, TTL/CMOS compatible; external 5 V supply for isolated; internal 5 V supply for non-isolated Four Relay Option: dual 7A relays and dual 1 A relays Analog Output: 0-5 V/1-5 V/0-10 V/0-20 mA/4-20 mA, user selectable; 354 Vp isolation; 14-bit resolution; 0.1% accuracy, 50 msec step response RS-232 Communications: /2400/4800/9600/19.2k baud; RJ11 4-wire connection; complete program setup and message display capability; programmable to transmit current display, alarm status, min / max, actual measured input value and status, supports continuous or command mode |