The OR700LCDRM1U Smart App LCD UPS from CyberPower protects and provides
power during a power failure for your workstations and network devices. The UPS
sports six surge protected 120V outlets, and four of the outlets can offer
battery power. It is designed to support up to 400W of equipment and conditions
incoming AC power utilizing Automatic Voltage Regulation technology. In the
event of a power outage, two internal batteries are on board to deliver up to 3
minutes of power at full loads or 11 minutes at half loads. Furthermore, an LCD
screen lets you access the features of the UPS system without using a
computer.
CyperPower provides PowerPanel Business Edition software that delivers
status notifications of the power supply via email, Windows Messenger, and XMPP
alerting. You can also avoid data loss as PowerPanel Business Edition
automatically shuts down your system in the event of a power loss to help avoid
data loss or damage to critical hardware components.
Remote Management
The Smart App Series offers full-featured network UPS management
capabilities with the PowerPanel Business Edition software and an optional SNMP
network management card. These remote management tools enable centralized power
management, monitoring, control, and configuration. They also provide for safe
shutdown of connected servers, workstations, and other devices via a standard
web browser or network management system (NMS).
Safe Shutdown
The PowerPanel Business Edition software, included with every Smart App
Sinewave UPS, enables an administrator to remotely manage each aspect of the UPS
and facilitate the orderly automatic shutdown of connected equipment in the
event of an extended power outage. This software also provides comprehensive
network power management for corporate servers and critical workstations
supported by the UPS, such as application/operating system shutdown, event
logging, reporting, alerts, and notifications.
Programmable Outlet Control
Smart App UPS systems allow programming of critical outlets and
non-critical outlets, giving administrators the ability to prioritize outlets
and increase battery backup runtimes for the most critical equipment during
extended power outages. Programmable outlet control also gives an administrator
the option to delay-start non-critical outlets, permitting the internal
batteries to fully recharge more quickly. This feature is vital to data centers
where seamless, uninterrupted equipment bootup is a necessity.
GreenPower UPS Technology
GreenPower UPS Technology from CyberPower consists of three different
energy-saving designs that improve operating efficiency, reduce heat generation,
and consume less power than conventional UPS models.
ECO Mode - is a form of bypass technology that can be switched on full
time, set for noncritical times (such as nights and weekends), or switched off.
This flexibility can help conserve power and save money.
Bypass Design - allows current to bypass the transformer and automatic
voltage regulation (AVR) when utility power is normal, thus reducing energy
consumption and associated costs. Because utility power functions normally most
of the time, the bypass design allows for energy savings. This technology also
reduces heat generation, an important factor in decreasing operating costs.
High-Efficiency Design - significantly decreases power consumption to
create an efficient backup battery for home and office use.
Power Protection without the Noise
CyberPower UPS systems harness high-efficiency ventilation, GreenPower UPS
technology, and innovative system components to ensure quiet operation.
Noise Filtering improves picture and sound quality in audio/video systems,
CyberPower uses advanced EMI/RFI noise filtering coils to decrease problems
caused by electromagnetic fields and radio frequency interference. The filters
smooth minor current fluctuations which cause disruptive humming and static.
Line Conditioning with automatic voltage regulation (AVR) prolongs the life
of sensitive electronic equipment. AVR line conditioning adjusts the incoming AC
voltage, keeping it within safe levels and reducing stress caused by power
fluctuations.
General
UPS Topology Line interactive
Energy Saving GreenPower UPS Bypass technology
ENERGY STAR Qualified Yes
Input
Voltage 90 to 140 VAC
Frequency Range 57 to 63 Hz
Plug Type NEMA 5-15P
Plug Style Straight
Output
VA 700 VA
Watts 400 W
Automatic Voltage Regulation (AVR) Yes
On Battery Voltage 120 VAC ± 10%
On Battery Frequency 60 Hz ± 1%
On Battery Waveform Simulated sine wave
Outlets Battery & surge protected: 4 x NEMA 5-15R
Surge-only protected: 2 x NEMA 5-15R
Overload Protection Internal circuitry limiting
Circuit breaker
Transfer Time 4 ms
Battery
Runtime at Half Load 11 minute
Runtime at Full Load 3 minutes
Battery Type Sealed lead-acid
Battery Size 6 V/9 Ah
Battery Quantity 2
User Replaceable Yes, with RB0690X2 replacement battery cartridge
Typical Recharge Time 8 hours
Protection and Filter
Surge Suppression 1,030 J
Phone RJ11 / Ethernet RJ45 1-in, 1-out (combo)
Management and Communications
LCD Panel Current/Load Level
Runtime
Battery Level
Input Voltage
Output Voltage
Battery In Use
Overload
Silent Mode
Normal Mode
HID Compliant USB Port Yes
Serial Port Yes
Management Cable USB cable
Serial cable
Alarms Battery Mode
Battery Low
Overload
UPS Fault
Replace Battery
SNMP/HTTP Remote Monitoring Yes, with optional RMCARD202, RMCARD203, or
RMCARD205
Environmental
Operating Temperature 32 to 95°F / 0 to 35°C
Operating Humidity 0 to 95% (non-condensing)
Certifications
Safety UL1778
cUL 107.1
FCC DOC Class B
Environmental RoHS Compliant
Physical
Form Factor 1RU
Cord Length 10.0' / 3.0 m
Dimensions (W x H x D) 17.3 x 1.8 x 9.3" / 438.2 x 44.5 x 235.0 mm
Weight 18.5 lb / 8.4 kg
Packaging Info
Package Weight 22.5 lb
Box Dimensions (LxWxH) 21.0 x 13.5 x 5.4"